Marrow Cellution

Patented BMA technology that minimizes blood dilution at the source, eliminating the centrifuge and maximizing cell capture without ever leaving the sterile field.

Marrow Cellution diagram

Rapid, Centrifuge-Free Aspiration with Clinically Significant Stem Cell Yields

 

Cervos Medical has redefined bone marrow aspiration (BMA) with Marrow Cellution. Traditional needles, designed for small volume harvesting in hematologic evaluations, often led to significant peripheral blood dilution and required additional centrifuge processing. Marrow Cellution solves this by minimizing blood dilution at the source, ensuring higher cell counts and maintaining sterility throughout the process.

key BENEFITS

Efficient Harvesting

Achieve aspirate-to-application in under 2 minutes, streamlining procedures and maximizing OR efficiency.

Sterile Integrity Maintained

The device operates entirely within the sterile field, automatically minimizing dilution and significantly reducing contamination risk.

Superior Cell Yield

Delivers a higher concentration of cells compared to centrifuge-based systems, as demonstrated by multiple peer-reviewed and independently tested studies.

Bone Marrow Aspiration, enhanced view

Clinical Evidence

Marrow Cellution™ Functionally Equivalent to Autograft
Analysis Sample
N=
CFU-f/mL
(Average)
TNC x 106/mL
(Average)
Cervos BMA2 5 5309 68.5
Cervos BMA3 5 4828 55.1
Cervos BMA4 5 5653 43.4
Cervos BMA5 22 4838 47.0
Cervos BMA Total 37 5010 50.5
Autograft1 10 4564 55.7

Data on File: 1.) Muschler, 2.) Bianco, 3.) Tortland, 4.) Scarpone, 5.) Lutz

There are now over seventeen peer-reviewed journal articles and papers across thousands of patients demonstrating the effectiveness of Cervos Marrow Cellution technology in multiple clinical settings.  For the complete updated list contact us.

Discover the Proprietary Features of the Patented Marrow Cellution BMA Device

 
Explore the assembled device with the aspiration cannula attached below. For detailed instructions and technique guides, please refer to the IFU.

Indicator

Indicator set perpendicular to handle ensures proper aspiration cannula alignment

Screw Mechanism

Allows for precise relocation into multiple regions of undisturbed cancellous bone, actuated by a 360 degree turn of the handle.

Blunted Outer Cannula

Rests against outer cortex to create leverage for screw.

Closed Distal Tip

Forces 100% of aspiration through side ports, blocking peripheral blood infiltration from distal end.